1. Home
  2. Industries

Start with where it mounts,then what to use

The same grade can behave very differently by industry — automotive needs temperature and vibration durability, electronics needs thin stacks with clean removal, buildings need weathering. This page expands typical parts, selection factors, common material families, and converting forms so engineers can match the job.

Align first Part · substrate · gap · environment Then specify Material family · die-cut form · line feed
01 / AUTO

Automotive

TRIM · BADGE · INTERIOR · NVH
Trim · nameplates · interior fixings

Body and interior see temperature cycling, vibration, and low-fogging limits together. Exterior trim and badges need shear strength through thermal shock; harness and buzz points need compressible foam; displays and pack neighborhoods need insulation, cushioning, and thermal barriers.

Typical parts
Exterior bright trim and badge bonding; door/headliner harness fix and buzz control; display cushioning and light-blocking foam; pack-adjacent thermal cushions and insulating pads.
Selection focus
High-energy metals/glass vs LSE PP/ABS/powder coat; long-term heat and low fogging; static shear vs dynamic vibration; sheets for hand apply vs rolls for automation.
Common materials
Acrylic foam DSA, VHB, PET-backed tapes; match SEKISUI / NITTO / tesa foam and tape families to the substrate.
Converting
PSA laminating, flatbed parts with pull-tabs/liners, and rotary rolls when the line needs continuous place.
On-site reference already used here: about −40~105 °C, vibration durability, low fogging. Final grades still follow substrate and drawings.
02 / ELECTRONICS

Electronics & electrical

CUSHION · INSULATION · THERMAL
Cushioning · insulation · thermal

Consumer electronics and electrical assemblies clamp thickness, residue, and cleanliness. Display PSA must die-cut to narrow bezels; FPCs need stiffeners and grounding; chips and heat sinks need compressible TIMs; speaker meshes need stable PSA without ooze.

Typical parts
Phone/tablet display PSA and narrow-bezel die-cuts; FPC stiffening and conductive ground; chip/heat-sink TIM fill; speaker mesh PSA.
Selection focus
Ultra-thin tolerance and step absorption; low residue / rework; halogen-free and cleanliness; sheet, kiss-cut, or roll/reel with datum holes.
Common materials
Ultra-thin PET DSA, thermal pads, conductive cloth/foil, PI tape; PORON / INOAC cushions and ThermoSil TIMs.
Converting
Precision die-cutting, slitting, and blanking; high volume often uses rotary rolls and reels for nozzle or label-head lines.
Electronics prioritizes thin, stable, clean removal. For TIMs, lock gap and compression ratio before hardness and heat path.
03 / SIGNAGE

Signage & labels

MOUNTING · OUTDOOR WEATHER
Drill-free wall mount · outdoor weatherability

Signs and wayfinding must hold on metal, acrylic, and glass, and survive outdoor UV plus thermal cycling. Drill-free wall mount needs high tack with lasting shear; lightbox panels need clear, low-print bonds.

Typical parts
Acrylic/metal lettering without drilling; outdoor directories under UV and thermal cycling; lightbox panels with clear low-print bonds; indoor graphics that need repositioning.
Selection focus
Substrate cleanliness and texture; expected outdoor life; tack vs final strength; need for repositionability.
Common materials
Acrylic foam tapes, PE foam tapes, transfer tapes; match thickness and tack to outdoor/indoor duty and panel weight.
Converting
Die-cut to letter/panel shapes with PSA and slitting so field cutting stays minimal.
Existing on-page reference: outdoor weathering is often discussed in a 3~5 year band, still subject to climate and substrate tests.
04 / BUILDING

Building windows & doors

SEAL · SOUND · CUSHION
Sealing · sound control · vibration damping

Fenestration and curtain wall care about airtightness, water tightness, and long-term recovery. Frame gaps need compressible seals; glass-to-profile joints need thermal and vibration pads; structural bonds and foam assists must stay clearly separated.

Typical parts
Curtain-wall assist bonding and cushioning; window/door air- and water-seal foam; IGU thermal/vibration pads; profile joints and hardware seals.
Selection focus
Compression ratio and long-term set; waterproof/acoustic targets; weathering and install temperature; continuous strip vs blanked pads.
Common materials
EPDM/CR foams, silicone seal systems, butyl seals; BISCO silicone foams and acrylic foam tapes by gap.
Converting
Blanking, PSA laminating, and continuous strip slitting for nest-in or pre-stick install.
Measure min/max gap before hardness and recovery. Do not reuse structural-bond assumptions for seal cushions.
05 / APPLIANCE

Appliances

PANEL BOND · NVH
Panel bonding · noise reduction

Appliance lines move fast — panel, glass, and sheet-metal bonds must land once; compressors and fans need NVH foam; harness near heat zones also bring temperature, flame, and cleaner resistance into scope.

Typical parts
Refrigerator/dishwasher panel and glass bonding; compressor/fan NVH foam; heat-tolerant harness fix and flame-resistant insulation; door-seal and trim assists.
Selection focus
Low odor and flame needs; cleaner/condensate resistance; hand-apply tabs vs automated rolls; show surfaces sensitive to print-through.
Common materials
VHB, PE foam, silicone gaskets; choose acrylic foam or compressible foam by panel material and load.
Converting
Mostly die-cutting and blanking; volume parts can ship as reels or rolls to cut line-side trimming.
For show surfaces, confirm ooze/print-through risk first. When flame or low-odor rules apply, send the compliance list with the drawing.
06 / TELECOM

Telecom equipment

EMI · SEAL · THERMAL
Shielding · sealing · thermal

Base stations and cabinets need waterproofing, shielding, and heat paths at once. Outdoor cavities rely on seals against weather; RF modules need compressible conductive gaskets; optics and amplifiers move heat across a controlled gap.

Typical parts
5G outdoor cavity weather seals; RF module EMI gaskets; optics/PA thermal interface pads; cabinet door and filter perimeter seals.
Selection focus
IP sealing under compression; conductivity/shielding needs; heat path vs available crush; outdoor aging and service disassembly.
Common materials
Conductive foam, silicone TIM pads, aluminum foil tape, weather seals; pick ThermoSil / BISCO / PORON by electrical and thermal path.
Converting
Blanking and laminating dominate; seals and gaskets follow cavity drawings, with PSA pre-stick when useful.
EMI and thermal often need two material sets: lock conductive contact and thermal gap first, then hardness and thickness.
How to choose

Describe conditions first, then the material

Temperature, gap, substrate, and line feed — once those four are clear, we can name grades and alternates. If unsure, send a sample or drawing and we will prototype.

01

Substrates

High-energy metals/glass, or LSE PP/PE/powder coat? Roughness, oil, and curvature also change tack and final strength.

02

Gap & stress

How much stack-up to fill, and what compression ratio? Static shear holding, or drop/vibration dynamics?

03

Environment & compliance

Short/long heat, outdoor UV and humidity, flame, low VOC/fogging, halogen-free — circle the must-haves first.

04

Assembly & delivery

Hand apply wants tabs and easy liners; automated place or nozzles prefer rotary rolls, datum holes, or reels.

Describe the conditions,
we'll name the grade.

Substrate, gap, temperature, volume—clear those four and the reply can name grades and alternates directly.

Ask an engineer to select →